Double 85 DC LINK Capacitor With Pin Type
- RUVA
- CHINA
- 3 Weeks
1. High CV product, compact
2. Good self-healing properties
3. Over-voltage capability
4. Low losses with high current capability
5. High reliability
6. Long useful life
7. RoHS-compatible
THB DC-LINK Metalized Polypropylene Film Capacitor - YHKS Series
INTRODUCTION
CONSTRUCTION
Dielectric: Polypropylene (MKP)
PPS Plastic case (UL 94 V-0)
Epoxy resin sealing (UL 94 V-0)
FEATURES
High CV product, compact
Good self-healing properties
Over-voltage capability
Low losses with high current capability
High reliability
Long useful life
RoHS-compatible
APPLICATIONS
Frequency converters
Industrial and high-end power supplies
Solar Inverters
CLIMATIC
Max. operating temperature: 105 °C (case)
Climatic category (IEC 60068-1): 40/105/56
TERMINALS
Parallel wire leads, lead-free tinned
2-pins, 4-pins, versions
Standard lead lengths: 5±1 mm
OUTLINE DRAWING
MARKING
TECHNICAL PARAMETERS
Reference standard | GB/T 17702-2013(IEC 61071:2007 ) GB/T 2693-2001(IEC 60384-1:2008 ) IEC 60068 |
Climatic category | 40/105/56 |
Operating temperature range (case) | Max. operating temperature, Top +105℃ Lower category temperature Tmin -40℃ |
For temperatures between 85 °C and 105 °C | 1.33%/°C of Vop derating compared to Vop @85 °C |
Rated voltage (VR) 85℃ | 500VDC/600VDC/800VDC/900VDC/1000VDC 1100VDC/1200VDC |
Capacitance tolerance | J (±5%) ; K (±10%) |
DC test voltage between terminals (10s) | 1.5 x VR |
Voltage test terminal to case (10s) | 2100 V AC, 50 Hz |
Insulation Resistance | > 10 000 s ( 20℃, 100vdc, 1min) |
Maximum peak current | IP=C*dV/dT |
Operation life time | 60 000 h at VR and 85℃ |
TYPICAL WAVEFORM
RESTRICTIONS
VR: Maximum operating peak voltage of either polarity but of a non-reversing waveform, for which the capacitor has been designed for continuous operation. VAC≤0.2*VR
NOTE 1
An over voltage equal to 1.5 * VR for 30 ms is permitted 1000 times during the life of the capacitor.The amplitudes of the over voltage that may be tolerated without significant reduction in the life time of the capacitor depend on their duration, the number of application and the capacitor temperature.In addition, these values assume that the over voltage may appear when the internal temperature of the capacitor is less than 0 ℃ but within the temperature category.
NOTE 2
The average applied voltage must not be higher than the specified voltage
TECHNICAL DATA
VR=500Vdc at 85℃ | |||||||||||
C (μF) | W ±1 | H ±1 | T ±1 | P ±0.5 | P2 ±0.5 | d ±0.05 | dV/dt (V/us) | Tgδ*10-4 | ESR@10 kHz (mΩ) | Irms(A) | |
1kHz | 10kHz | ||||||||||
5 | 32 | 21 | 11 | 27.5 | - | 0.8 | 30 | 12 | 120 | 25 | 3.0 |
10 | 32 | 24.5 | 15 | 27.5 | - | 0.8 | 30 | 12 | 120 | 7.5 | 6.5 |
22 | 32 | 36.5 | 22 | 27.5 | - | 1.0 | 30 | 12 | 120 | 5.0 | 10.0 |
30 | 42 | 40 | 20 | 37.5 | 10.2 | 1.0 | 21 | 22 | 220 | 8.0 | 12.5 |
35 | 42 | 36 | 24 | 37.5 | 10.2 | 1.0 | 21 | 22 | 230 | 8.0 | 13.5 |